Goodman Furnace Error Codes and Blinking Lights
Goodman and Amana furnace error codes from Goodman's own service manuals: how to read the display safely, what E0, E1, E2 and others mean, and when to call.
Read the guide
Furnace repair in Belle Plaine starts with a $79 trip charge, waived when you approve it, on CenterPoint gas or farm propane. A no-heat call goes to the front of the line. Older houses near downtown often vent the furnace into a chimney shared with the water heater.
The older houses near downtown Belle Plaine often have small basements with low ceilings and narrow stairs, and the furnace sits wherever it fit, sometimes with a flue connector running at a shallow pitch to a chimney shared with the water heater. Repairs there take patience, since testing an inducer or pulling a blower happens in a space where you can't stand up. A connector with too little rise can also let exhaust linger and rust through, so that connector deserves a look on any furnace or water-heater service here.
The 2000s subdivisions are easier to work in and now old enough for their first real failures. Builder-grade furnaces from that era often lose inducer motors, pressure switches and control boards somewhere past the 15-year mark. On the farms outside town, propane furnaces add regulator and gas-pressure checks to the list.
Updated November 10, 2026
National averages (HomeGuide, 2026), not our prices: a variable-speed (ECM) blower motor $800–$2,300, an igniter $100–$250, a flame sensor $80–$250. More in the furnace repair cost guide.
Symptom guides: Strange noises · Leaking water · Burning smell · Red tag · Signs your furnace needs a technician
It can be. On an 80% furnace, the metal connector carries exhaust from the draft hood to the chimney, and rust usually means moisture is condensing inside because the flue gas cools before it's out. Rust holes let exhaust, including carbon monoxide, into the basement. We check the pipe's pitch and joints, test draft and CO, and replace corroded sections. Minnesota requires CO alarms within 10 feet of sleeping rooms, so test yours too.
At that age, usually. Furnaces from Belle Plaine's 2000s subdivisions tend to fail one part at a time, and the flashing code on the control board points toward the circuit that stopped the startup, often the pressure switch or the inducer. Write down the flash pattern before you cycle the power, since a reset can clear it. We confirm with meter readings and give you a written price.
Goodman and Amana furnace error codes from Goodman's own service manuals: how to read the display safely, what E0, E1, E2 and others mean, and when to call.
Read the guideBryant's Evolution 987M modulates; Legacy furnaces are single-stage. What that means in a Minnesota winter, how warranties compare, and where Preferred fits.
Read the guideA 98% AFUE furnace saves only about 2% more gas than a 96% model. Our condensing furnaces run $6,500–$9,500 installed. See what the extra buys.